Availability: | |
---|---|
Quantity: | |
MTPG10
Mantern
1. Instrument Charging time: 3 to 6 hours
2. Charging voltage: DC5V (DC)
3. Using time: about 20 hours of gas, other gases than a week
4. Detection of gas type: oxygen, combustible gas, carbon monoxide, hydrogen sulfide and other toxic gases
5. Working environment: Temperature 0 ~ 50 °; relative humidity <95%
6. Response time: oxygen <30S; monoxide <40S; combustible <20S; hydrogen sulfide <40S (other omitted).
7. Instrument Dimensions: L * W * H; 108mm × 61mm × 40mm
8. Alarm: sound, light, vibration alarm
Measured gas | Technical indicators | |||
Measurement Range | Resolution | Alarm | ||
CO | Carbon monoxide | 0-1000ppm | 1ppm | 50ppm |
H2S | Hydrogen sulfide | 0-100ppm | 1ppm | 10ppm |
H2 | Hydrogen | 0-1000ppm | 1ppm | 35ppm |
SO2 | Sulfur dioxide | 0-100ppm | 1ppm | 5ppm |
NH3 | Ammonia | 0-200ppm | 1ppm | 35ppm |
NO | Nitric oxide | 0-200ppm | 1ppm | 35ppm |
NO2 | Nitrogen dioxide | 0-20ppm | 1ppm | 5ppm |
CL2 | Chlorine | 0-20ppm | 1ppm | 2ppm |
O3 | Ozone | 0-50ppm | 1ppm | 2ppm |
O2 | Oxygen | 0-30%vol | 0.1%vol | below 18%vol above 23%vol |
EX | Flammable | 0-100%LEL | 1%LEL | 25%LEL |
CO2 | Carbon Dioxide | 0-5%vol | 0.001%vol | 0.2%vol |
1. Instrument Charging time: 3 to 6 hours
2. Charging voltage: DC5V (DC)
3. Using time: about 20 hours of gas, other gases than a week
4. Detection of gas type: oxygen, combustible gas, carbon monoxide, hydrogen sulfide and other toxic gases
5. Working environment: Temperature 0 ~ 50 °; relative humidity <95%
6. Response time: oxygen <30S; monoxide <40S; combustible <20S; hydrogen sulfide <40S (other omitted).
7. Instrument Dimensions: L * W * H; 108mm × 61mm × 40mm
8. Alarm: sound, light, vibration alarm
Measured gas | Technical indicators | |||
Measurement Range | Resolution | Alarm | ||
CO | Carbon monoxide | 0-1000ppm | 1ppm | 50ppm |
H2S | Hydrogen sulfide | 0-100ppm | 1ppm | 10ppm |
H2 | Hydrogen | 0-1000ppm | 1ppm | 35ppm |
SO2 | Sulfur dioxide | 0-100ppm | 1ppm | 5ppm |
NH3 | Ammonia | 0-200ppm | 1ppm | 35ppm |
NO | Nitric oxide | 0-200ppm | 1ppm | 35ppm |
NO2 | Nitrogen dioxide | 0-20ppm | 1ppm | 5ppm |
CL2 | Chlorine | 0-20ppm | 1ppm | 2ppm |
O3 | Ozone | 0-50ppm | 1ppm | 2ppm |
O2 | Oxygen | 0-30%vol | 0.1%vol | below 18%vol above 23%vol |
EX | Flammable | 0-100%LEL | 1%LEL | 25%LEL |
CO2 | Carbon Dioxide | 0-5%vol | 0.001%vol | 0.2%vol |
Mantern Industrial Co., Ltd. is engaged in international business since 2012. Our aim is to provide good products with competitive price for our clients.